Relay Output | Channel: 4 channels Type: Form C Connector: 3 x plug-in terminal blocks Contact current rating: 10A @12VDC/5A @24VDC |
Digital Input | Channel: 4 channels Sensor type: wet contact (default)/dry contact I/O mode: DI Wet contact: 9 to 36V, 12V @ 1.1mA/24V @ 2.2mA Dry contact: external 0 to 36V Wet or dry contact should be selected by SW utility |
Digital Output | Channel: 4 channels Sensor type: wet contact (default)/dry contact I/O mode: DO Wet contact: 9 to 36V, 9V @13.2mA/12V @17.6mA/24V @25.29 mA/ 36V @52.7mA Dry contact: external 0 to 36V Wet or dry contact should be selected by SW utility |
Analog Input | Channel: 1 channel Resolution: 10 bits I/O mode: voltage/current input Input range: 0 to 36V, 0 to 3A |
Frequency Input | Channel: 1 channel I/O mode: frequency (PWM) input Input frequency range: 2Hz to 6KHz |
Power Requirements | Input voltage: 9 to 36 VDC Input current: 70mA @12 VDC |
I/O Interface-Relay Side | 4 x Relay’s 3 plug-in terminal blocks for N.O./COM/N.C. 4 x LED indicator for activated relays 1 to 4 |
I/O Interface-IO Side | 1 x DB9 for RS-232 1 x Type A USB 2.0 1 x DC input 9~36V (3 plug-in terminal block for VIN/IGN/GND) |
I/O Interface-COM/USB Side | 1 x 10 plug-in terminal blocks for 4 x DI/4 x DO/ISO PW/ISO GND 1 x 4 plug-in terminal blocks for Analog Input/Frequency Input/ISO GND |
Operating System | Windows driver Linux (by request) |
Dimensions | 124mm (W) x 126mm (D) x 24mm (H) (4.88” x 4.96” x 0.94”) Weight: 0.42kg (0.9lbs) |
Environment |
Temperature - Operating temperatures: -40°C to 85°C - Storage temperatures: -45°C to 85°C - Damp heat test per EN60068-2-30 Humidity - IEC60068-2-3, damp heat steady state test, 40C, 95%, 48hrs Vibration - IEC 60068-2-64, 2G - Operating: MIL-STD-810G, 514.6C Procedure 1, Category 4 - Storage: MIL-STD-810G, 514.6E Procedure 1, Category 24 Shock - MIL-STD-810G, 516.6 Procedure I, trucks and semi-trailers=40g - Crash hazard: Procedure V, ground equipment=75g |
Certifications (compatible) | CE FCC Class B |